Engineering
MP-002@miro-bench-a
Overview
Requirements
Design
Changes
Agreements
Research
Loading…
MP-002
Overview
Requirements
Design
Changes
Agreements
Research
Records
Qualification
2/2
All
▼
Add
Defined
A label card must keep both corner references and remain removable
REQ-1121
Requirement statement
The fixture must retain a repeatable card position without making it impossible to change the teaching example.
Acceptance criterion
Both corner marks stay indexed after the archived motion, and the card can be withdrawn with the same pin arrangement.
Verification method
Compare both corner marks on the card and inspect the removal view for the paired pins.
Source
Single and paired index pins on the card jig
Linked evidence review
Review pending
Applies to
Miro payload inspection interface · Rev A · MP-002
Requirement traceability
Component CFG-1121
· Engineering · Design · Components
Evidence Inspection · Nov 22, 2026, 2:21 PM UTC
· Verification · Vibration
Change CHG-1121
· Engineering · Changes
Notes
Add note
Approved
Signed inspection sheet names the individual article
REQ-936
Requirement statement
The witness index shall retain the inspected article label and the signed inspection sheet.
Acceptance criterion
The index opens the signed sheet for the same recorded article.
Verification method
Archive record comparison
Source
Unavailable
Linked evidence review
Follow-up needed
Filed references
2 unavailable in this selection.
Applies to
Miro payload inspection interface · Rev A · MP-001, MP-002
Requirement traceability
Interface IF-936
· Engineering · Design · Interfaces
Inspection sheet and witness archive
· Verification · Proof pressure
Notes
Add note